50W MIL AC-DC or DC-DC converters
NOTE: THE AM SERIES IS NOT RECOMMENDED FOR NEW DESIGNS DUE TO PARTS OBSOLESCENCE. WE RECOMMEND THE RM SERIES AS A {bfb} COMPATIBLE DIRECT REPLACEMENT.
|
|
Features
|
Fully rated for -55C to 100C
|
Fixed Frequency Power Conversion
|
MIL-STD-810D
|
MIL-S-901C
|
Remote Turn-On (TTL)
|
Not recommended for new designs
|
|
Input Characteristics
|
Min
|
Max
|
Typical
|
Units/Comments
|
Input Voltage Range
|
100
|
300
|
|
270 VDC, Nominal
|
|
90
|
130
|
|
VAC, 47-400HZ, 1-3 PHASE
|
|
180
|
260
|
|
VAC, 47-400HZ, 1-3 PHASE
|
Efficiency Range:
|
|
|
60% min
|
|
|
|
|
|
|
Output Characteristics
|
Min
|
Max
|
Typical
|
Units/Comments
|
Output Power(Max.):
|
|
50
|
|
Watts
|
Number of Outputs:
|
|
3
|
|
|
|
|
|
|
|
Model
|
Main Output Voltage (VDC)
|
Aux 1 Nom. Vout (VDC)
|
Aux 2 Nom. Vout (VDC)
|
Main Output Current (Amps)
|
Aux 1 Output Current (Amps)
|
Aux 2 Output Current (Amps)
|
AM50T/5/12
|
5
|
12
|
-12
|
7
|
0.64
|
-0.64
|
AM50T/5/15
|
5
|
15
|
-15
|
7
|
0.5
|
-0.5
|
|
|
|
|
|
|
Short Circuit:
|
|
|
Indefinite, Auto Recovery
|
|
Minimum Load:
|
|
|
0
|
|
Load Regulation:
|
|
|
10mV OR 0.1%, whichever is greater; AUX : 150mV
|
|
Line Regulation:
|
|
|
10mV OR 0.1%, whichever is greater; Aux: 0.5% MAX
|
|
Ripple/Noise:
|
|
|
100mV pp for 5V; 200m Vpp for others
|
|
|
|
|
|
|
Isolation Characteristics
|
|
Input to Output:
|
1000 Vdc min.
|
Output to Base:
|
200 Vdc min.
|
|
|
|
|
|
Environmental Characteristics
|
|
Operating Temperature:
|
-55 to 100 °C
|
Storage Temperature:
|
-55 to 125 °C
|
|
|
|
|
|
Mechanical Characteristics
|
|
Dimensions:
|
3.50 x 4.50 x 0.85 inches
|
|
|
|
|
|
Applicable Standards
|
|
EMI
|
MAJORITY OF MIL-STD-461C
|
MIL-STD-704A
|
MIL-STD-704D
|
MIL-STD-1399
|