Model: NL-FYK-2
The air pressure switch is the head safety gate of the flue-gas chain in gas water heaters and wall boilers: failing to act on blocked flue is an accident, and a drifting actuation point becomes ignition failures and warranty tickets. Incoming checks that only puff air and read continuity leave the actuation pressure, the drift after tens of thousands of cycles and the NO or NC type all undocumented, so every new supplier or batch restarts the risk.
The bench serves performance testing and endurance life testing of air pressure switches of all models used in gas appliances. Two stations run endurance tests at the same time, each controlled independently. A gas booster produces 0 to 1MPa output from a 5 to 15MPa nitrogen source supplied by the customer, regulated by PID or manually for a stable and reliable supply. Pneumatic output spans 0.1Pa to 1MPa in positive pressure with plus or minus 1 percent accuracy, covering both the millipascal actuation range and the high-pressure proof range. The circuit follows the standard sequence automatically: the PLC drives the main regulating solenoid valve to set the output pressure, a stabiliser and back-pressure valve split and steady the flow delivered to the specimen, and after the specimen actuates the flow returns through the water pipe to the venting solenoid valve for depressurisation. Test rate is 15 to 50 cycles per min, on-off time 1 to 999s and count range 0 to 99999999, stopping automatically at the set count. During the test the bench detects automatically whether the switch is normally open or normally closed. One endurance cycle counts once; a faulty switch stops only its own station with an audible and visual notice while the other keeps running. Test data survive power loss. Control is a Xinje PLC with touch screen, and fixtures include a 7/16-20 internal-thread tooling clamp and a 6.35mm copper-tube sealing clamp, with NMB or equivalent high-pressure solenoid valves.


GB/T 14536.7-2024 Automatic electrical controls, Part 7 Particular requirements for automatic electrical pressure sensing controls including mechanical requirements (current, effective 2025-05-01, identical to IEC 60730-2-6:2015, replacing GB/T 14536.7-2010); GB/T 14536.1-2022 Part 1 General requirements; appliance references GB 6932-2015 domestic gas instantaneous water heaters and GB 25034-2020 gas heating and hot water combi boilers; actuation points, cycles and judgement follow the customer technical agreement or product drawing.
Batch inspection and type testing at air pressure switch factories; incoming inspection at gas water heater and wall-hung boiler plants; actuation and endurance verification in third-party laboratories; comparison after supplier or diaphragm changes
Guangdong Endurance Electronic Equipment Co., Ltd provides non-standard customization, drawing confirmation, factory acceptance, on-site installation and commissioning, operation training and long-term technical service; 12-month warranty and long-term spare parts supply. Tel: 0760-88500902 / 13416787649. Web: en.zsnaili.com.