Air Pressure Switch Endurance Test Bench NL-FYK-2 Two Stations 0.1Pa to 1MPa Wide Range NO-NC Auto Detection 15-50 Cycles per Min Nitrogen PID 99999999 Counts GB/T 14536.7-2024 Gas Water Heater Wall Boiler Pressure Switch Testing

    面议

    Guangdong Endurance Electronic Equipment Co., Ltd

    进入店铺
    商品目录
    图文详情

    Model: NL-FYK-2

    The problem

    The air pressure switch is the head safety gate of the flue-gas chain in gas water heaters and wall boilers: failing to act on blocked flue is an accident, and a drifting actuation point becomes ignition failures and warranty tickets. Incoming checks that only puff air and read continuity leave the actuation pressure, the drift after tens of thousands of cycles and the NO or NC type all undocumented, so every new supplier or batch restarts the risk.

    Capability

    The bench serves performance testing and endurance life testing of air pressure switches of all models used in gas appliances. Two stations run endurance tests at the same time, each controlled independently. A gas booster produces 0 to 1MPa output from a 5 to 15MPa nitrogen source supplied by the customer, regulated by PID or manually for a stable and reliable supply. Pneumatic output spans 0.1Pa to 1MPa in positive pressure with plus or minus 1 percent accuracy, covering both the millipascal actuation range and the high-pressure proof range. The circuit follows the standard sequence automatically: the PLC drives the main regulating solenoid valve to set the output pressure, a stabiliser and back-pressure valve split and steady the flow delivered to the specimen, and after the specimen actuates the flow returns through the water pipe to the venting solenoid valve for depressurisation. Test rate is 15 to 50 cycles per min, on-off time 1 to 999s and count range 0 to 99999999, stopping automatically at the set count. During the test the bench detects automatically whether the switch is normally open or normally closed. One endurance cycle counts once; a faulty switch stops only its own station with an audible and visual notice while the other keeps running. Test data survive power loss. Control is a Xinje PLC with touch screen, and fixtures include a 7/16-20 internal-thread tooling clamp and a 6.35mm copper-tube sealing clamp, with NMB or equivalent high-pressure solenoid valves.

    NL test equipment

    NL test equipment

    Applicable standards

    GB/T 14536.7-2024 Automatic electrical controls, Part 7 Particular requirements for automatic electrical pressure sensing controls including mechanical requirements (current, effective 2025-05-01, identical to IEC 60730-2-6:2015, replacing GB/T 14536.7-2010); GB/T 14536.1-2022 Part 1 General requirements; appliance references GB 6932-2015 domestic gas instantaneous water heaters and GB 25034-2020 gas heating and hot water combi boilers; actuation points, cycles and judgement follow the customer technical agreement or product drawing.

    Key specifications

    • Stations: 2, independently controlled, simultaneous endurance testing
    • Pneumatic output: 0.1Pa to 1MPa (gas booster, positive pressure)
    • Pressure accuracy: plus or minus 1 percent
    • Gas source: 5 to 15MPa nitrogen (customer supplied), PID or manual regulation
    • Pneumatic path: regulating valve - stabiliser and back-pressure valve - specimen - return pipe - venting valve
    • Test rate: 15 to 50 cycles per min
    • On-off time: 1 to 999s adjustable
    • Count range: 0 to 99999999, automatic stop at set count
    • Type detection: automatic NO / NC recognition
    • Fault handling: faulty station stops with audible and visual notice, other station continues
    • Data: power-loss memory, touch screen digital display
    • Control: Xinje PLC plus touch screen
    • Fixtures: 7/16-20 internal-thread clamp; 6.35mm copper-tube sealing clamp
    • High-pressure solenoid valves: NMB or equivalent

    Applications

    Batch inspection and type testing at air pressure switch factories; incoming inspection at gas water heater and wall-hung boiler plants; actuation and endurance verification in third-party laboratories; comparison after supplier or diaphragm changes

    About the manufacturer

    Guangdong Endurance Electronic Equipment Co., Ltd provides non-standard customization, drawing confirmation, factory acceptance, on-site installation and commissioning, operation training and long-term technical service; 12-month warranty and long-term spare parts supply. Tel: 0760-88500902 / 13416787649. Web: en.zsnaili.com.

    郑重声明:产品 【Air Pressure Switch Endurance Test Bench NL-FYK-2 Two Stations 0.1Pa to 1MPa Wide Range NO-NC Auto Detection 15-50 Cycles per Min Nitrogen PID 99999999 Counts GB/T 14536.7-2024 Gas Water Heater Wall Boiler Pressure Switch Testing】由 Guangdong Endurance Electronic Equipment Co., Ltd 发布,版权归原作者及其所在单位,其原创性以及文中陈述文字和内容未经(企业库qiyeku.cn)证实,请读者仅作参考,并请自行核实相关内容。若本文有侵犯到您的版权, 请你提供相关证明及申请并与我们联系(qiyeku # qq.com)或【在线投诉】,我们审核后将会尽快处理。